) AKREOS® AO MICS | Bausch + Lomb Surgical

AKREOS® AO MICS

CAPTURE THE ESSENCE OF YOUR PATIENTS EVERYONE’S EYES ARE UNIQUE

Benefits of the Akreos® IOLs with Advanced Optics (AO) Technology

  • Thanks to the design of their optic, they do not introduce higher-order aberrations, providing a better quality of vision 1.2
  • Uniform power from the center to the periphery of the optic, for a predictable visual outcome in all patients regardless of the shape of the cornea, size and center of the pupil or the capsular bag
  • They maintain the natural positive spherical aberration of the cornea, which may resultin a greater depth of field compared with aberration correcting IOLs3

The Akreos® platform has an aspheric design that adapts to a wide range of patients*

The optical performance of an IOL with AO technology should be better than that of a standard spherical IOL1

The Akreos® AO MICS and Akreos® AO lenses are crafted from an acrylic hydrophilic material that makes it optimal for today’s micro incision cataract surgery requirements. The lenses can be easily compressed to fit through a 1.8 mm incision; it unfolds smoothly once implanted into the eye and recovers its initial shape without damage.

  • Minimize the surgically induced corneal astigmatism (SIA)1,2 and preserve optical properties of the cornea1,3
  • Minimally traumatic surgery, providing better postoperative outcomes than standard small incision phacoemulsification1
  • MICS favors the use of fluidics, reducing the use of phacoemulsification power1
  • Reduces the risk for intraoperative anterior chamber instability4
  • Less incision bleeding during the surgery4
  • Higher structural stability of the anterior chamber4
  • Easy in construction and less incidence of postoperative endophthalmitis4

 

product information

MATERIAL

  • Hydrophilic acrylic
  • 26 % water content
  • UV Filter

Refractive index: 1.46

DESIGN

  • Monofocal aberration-free aspheric optic
  • 360° posterior square edge
  • Haptic angulation 10°
  • One-piece IOL with four-point fixation
  • Orientation features to indicate the anterior side (top right and bottom left)

OPTIC DIAMETER

  • 6.2 mm: 0.00 D to +15.00 D
  • 6.0 mm: +15.50 D to +22.00 D
  • 5.6 mm: +22.50 D to +30.00 D

OVERALL DIAMETER

  • 11.0 mm: 0.00 D to +15.00 D
  • 10.7 mm: +15.50 D to +22.00 D
  • 10.5 mm: +22.50 D to +30.00 D

DIOPTER RANGE

  • D to +30.00 D
  • D to +10.00 D (increments of 1.00 D)
  • +10.00 D to +30.00 D (increments of 0.50 D)

INJECTORS

  • Viscoject™ BIO 1.8 (10 Units/box) Ref: LP604350C | Recommended incision size: 1.8 mm (Wound assist technique)

OPTIC CONSTANT

  • A-Constant SRK/T: 119.1
  • ACD: 5.67
  • Surgeon factor: 1.90
  • Haigis: a0: 1.49 / a1: 0.40 / a2: 0.10

ULTRASONIC CONSTANT

  • A-Constant: 118.4
  • ACD: 5.20
  • Surgeon factor: 1.45