) Victus Femtosecond Laser Platform | Bausch + Lomb Surgical

VICTUS Femtosecond Laser Platform - Full Vision & Versatility

With thirty years of experience in the ophthalmic laser surgery field, the 3rd Generation VICTUS Femtosecond Laser Platform combines our expertise in surgeon and patient needs with German engineering and intuitive design.

The VICTUS Femtosecond Laser is a versatile platform with cataract, LASIK flap, and therapeutic indications. It features Swept Source (2S) OCT Technology for live, online, continuous viewing of the entire procedure for all procedures.

Summary of the features on the VICTUS Femtosecond Laser Platform

  •  Live online OCT view throughout entire procedure for all procedures for control and reassurance
  1. Full visualisation of cataract steps
  2. Full visualisation of LASIK Flaps
  3. Full visualisation of therapeutics
  4. Live OCT-supported adjustment of arcuate incisions
  • Intuitive Graphic User Interface for optimised treatment planning across all indications
  • Procedural planning to suit surgeon preference
  • Customisation for surgeon technique
  • Wide range of fragmentation patterns: spider web, grid, radial and circular
  • Auto-pupil centration for LASIK Flaps
  • Range of therapeutic indications
  • Curved Patient Interface with a large treatment zone to accommodate all treatment designs
  • Ergonomically designed headrest with integral joystick combined with 3D pressure sensors for controlled and intuitive docking

VICTUS® Femtosecond Laser Platform – CATARACT

The VICTUS Femtosecond Laser Platform performs key cataract surgery steps with accuracy and precision: 1-3

  • Capsulotomy
  • Lens fragmentation
  • Arcuate incisions
  • Primary/secondary incisions

Customised procedural planning to suit surgeon technique

The swept-source OCT technology and Advanced Identification Management System –AIMS– allow software-supported recognition of the relevant eye structures and customised procedural planning to suit the surgeon technique.

Range of fragmentation patterns

  • Grid, circular, radial or spider web pattern can be selected according to individual surgical technique and grade of cataract.
  • Energy can be adjusted according to cataract grade.
  • Lens fragmentation pattern optimised to fit lens shape and tilt.
  • Lens fragmentation grooves aligned with main incision.
  • Designed for use with Stellaris Activate and the Zero Phaco Handpiece

References:

1. Reddy KP, Kandulla J, Auffarth GU. Effective and safety of femtosecond laser-assisted lens fragmentation and anterior capsulotomy versus the manual technique in cataract surgery. J Cataract Refract Surg 2013; 39:1297–13062.

2. Chee SP, Yang Y, Ti Se. Clinical Outcomes in the First Two Years of Femtosecond Laser–Assisted Cataract Surgery. American Journal of Ophthalmology 2015; 159(4):714-719.

3. Daya SM, Nanavaty MA, Espinosa-Lagana MM. Translenticular hydrodissection, lens fragmentation, and influence on ultrasound power in femtosecond laser–assisted cataract surgery and refractive lens exchange. J Cataract Refract Surg 2014; 40:37–43 

Indications and approvals may vary by country. Please contact your Authorized Technolas Perfect Vision Representative for further information. *AKRUS Product

Legal Manufacturer: Technolas Perfect Vision GmbH

VICTUS® Femtosecond Laser Platform – THERAPEUTICS

A range of therapeutic indications are available on the VICTUS Femtosecond Laser:

Penetrating Keratoplasty (PKP), Lamellar Keratoplasty (LKP), tunnels for intrastromal corneal ring segments and pockets for crosslinking.

For all of the therapeutics indications, the VICTUS provides:

  • Intuitive treatment planning
  • OCT supported docking
  • OCT supported alignment
  • Live OCT visualisation throughout the laser treatment


Currently NOT available in all countries. Please contact your Authorized Technolas Perfect Vision Representative for further information.
Legal Manufacturer: Technolas Perfect Vision GmbH

VICTUS® Femtosecond Laser Platform – LASIK Flaps

The VICTUS Femtosecond Laser Platform provides customizable and predictable LASIK flaps.1

The procedure is performed at 160 kHz using regular docking where engagement parameters are designed to provide a stable corneal reference interface for precise depth control during the procedure.

 For the LASIK flap indication, the VICTUS provides:

  • Intuitive template-based treatment planning
  • Rim only possible
  • Flap hinge planning options: Nasal, Superior or Custom
  • Variable diameter: 6.0 - 9.5 mm
  • Selectable flap thickness
  • OCT supported docking
  • Auto pupil-centration
  • OCT supported treatment: Visualization of entire flap procedure including flap creation  
  • High resolution camera
  • High resolution, live OCT imaging during flap creation.

 

1. Endl M & Rousseau P. Corneal flap analysis of new Short Pulse Femto-LASIK with Optical Coherence Tomography. ASCRS 2014 Poster.

Indications and approvals may vary by country. Please contact your Authorized Technolas Perfect Vision Representative for further information. 

Legal Manufacture: Technolas Perfect Vision GmbH

VICTUS Femtosecond Laser SPECIFICATIONS

Laser TypeDiode-pumped solid state laser (DPSSL)
Wavelength1040+/-25nm
Pulse Frequency80 or 160 kHz depending on procedure
Pulse Duration290-550 fs
Power Supply230 VAC ~ 50/ Hz/60 Hz
Power ConsumptionMax. 3 KW
Weight640-690 kg, depending on configuration (without patient bed)
DimensionsL: 208.0 cm (without patient bed), L: 210:0 cm (with patient bed*), W: 83.0 cm, H: 168.0 cm
System ComponentsMain laser unit, Patient bed included, Sterile Patient Interface Kit
VisualisationReal-time, high contrast and high-speed Swept-Source OCT, High-resolution video microscope, Optional external microscope
Patient InterfaceIntelligent Pressure Sensors; Curved Patient Interface

Additional Information

Contact